7th Annual International Conference on Industrial Engineering and Operations Management

The Effect of Tube Replacement on The Operation of Primary Reformer in Ammonia Plant

Muhamad Fariz Failaka & Ali ElKamel
Publisher: IEOM Society International
0 Paper Citations
1 Views
1 Downloads
Track: Modeling and Simulation
Abstract

The primary reformer in Ammonia Plant is basically a furnace containing burners and tubes packed with supported nickel catalyst. The reformer operating parameters has an important influence on reduction of energy consumptions and increasing the reactor performance.

In this paper, the effect of tube replacement on the operation of primary reformer is investigated. Furthermore, the heat balance in the radiation and convection sections of primary reformer are studied using Aspen Plus software.

Published in: 7th Annual International Conference on Industrial Engineering and Operations Management, Rabat, Morocco

Publisher: IEOM Society International
Date of Conference: April 11-13, 2017

ISBN: 978-0-9855497-6-3
ISSN/E-ISSN: 2169-8767